Power Dialog Plus

6,5-10 kVA

The POWER DIALOG PLUS series includes the 6kVA single/single-phase and 6.5-8-10 kVA single/singlephase and three/single-phase models and uses double conversion
on-line technology (VFI). The load is powered continuously by the inverter with an EMI filtered, stabilised and regulated sinewave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges, even on bypass.
For technology, outstanding performance (selectable operating modes: On-line, Economy, Smart-Active and Standby/Off - for emergency lighting applications),
advanced diagnostics (standard LCD display, RS232 interfaces with PowerShield³ software included, EPO input contact, and a network interface slot), POWER DIALOG PLUS provides maximum protection for vital "mission-critical" networks and security applications (electromedical).
Additional battery extension packs allow the standard battery runtime to be extended up to several hours.
Note the simple installation: the UPS can be connected both to single-phase and three-phase mains supplies (PWP 650-1000).


• reliable, filtered, stabilised and regulated sinewave output (double conversion on-line
technology VFI according to EN50091-3 specifications with filters for atmospheric
disturbance suppression
• high reliability: full microprocessor control with nobreak static and manual by-pass
• high level diagnostics: states, measurements and alarms - available from the built-in LCD
• power factor correction with sinusoidal input to ensure a low impact on the mains supply (UPS input power factor, close to 1) for the single-phase/singlephase series
• very low noise level <40dB(A)
• low power consumption (“Economy Mode”, Smart Active Mode, and Standby/Off Mode to increase efficiency up to 98%)
– Economy Mode: uses Line Interactive (VI) technology to power less critical loads from the mains supply for certain periods. The function can be set from the front panel keypad or remotely using software
– Smart Active: if the mains supply is out of range, the UPS will power the load from the inverter as an Online UPS. When the mains supply returns to within range again, the UPS will monitor this for a certain period before selecting Line Interactive operation

– Standby/Off: for security applications like emergency lighting where the UPS is switched on but the loads are powered through the bypass supply. When the mains fails or falls outside a preset range the inverter automatically powers the load
• Simple to install:
– capability to connect the UPS both to single-phase and three-phase mains supplies
(PWP 650-800-1000 models)
– output terminal block + 2 IEC outlets for powering local equipment (computers, modems and notebooks)
• easy to position (integrated wheels)
• built-in automatic and manual battery test feature
• auto restart on mains return (programmable - software or from the front panel)
• back feed protection as standard: to avoid energy feeeding back into the mains supply
• integrated automatic and manual by-pass.

Show Technical datas